Inter-process communication (IPC) is a key part of building feature-rich desktop applications in Electron. Because the main and renderer processes have different responsibilities in Electron’s process model, IPC is the only way to perform many common tasks, such as calling a native API from your UI or triggering changes in your web contents from native menus.

IPC channels

In Electron, processes communicate by passing messages through developer-defined “channels” with the ipcMain and ipcRenderer modules. These channels are arbitrary (you can name them anything you want) and bidirectional (you can use the same channel name for both modules).

In this guide, we’ll be going over some fundamental IPC patterns with concrete examples that you can use as a reference for your app code.

Understanding context-isolated processes

Before proceeding to implementation details, you should be familiar with the idea of using a preload script to import Node.js and Electron modules in a context-isolated renderer process.

Pattern 1: Renderer to main (one-way)

To fire a one-way IPC message from a renderer process to the main process, you can use the ipcRenderer.send API to send a message that is then received by the ipcMain.on API.

You usually use this pattern to call a main process API from your web contents. We’ll demonstrate this pattern by creating a simple app that can programmatically change its window title.

For this demo, you’ll need to add code to your main process, your renderer process, and a preload script. The full code is below, but we’ll be explaining each file individually in the following sections.

```fiddle docs/fiddles/ipc/pattern-1


### 1. Listen for events with `ipcMain.on`

In the main process, set an IPC listener on the `set-title` channel with the `ipcMain.on` API:

```javascript {6-10,22} title='main.js (Main Process)'
const {app, BrowserWindow, ipcMain} = require('electron')
const path = require('path')

//...

function handleSetTitle (event, title) {
  const webContents = event.sender
  const win = BrowserWindow.fromWebContents(webContents)
  win.setTitle(title)
}

function createWindow () {
  const mainWindow = new BrowserWindow({
    webPreferences: {
      preload: path.join(__dirname, 'preload.js')
    }
  })
  mainWindow.loadFile('index.html')
}

app.whenReady().then(() => {
  ipcMain.on('set-title', handleSetTitle)
  createWindow()
}
//...

The above handleSetTitle callback has two parameters: an IpcMainEvent structure and a title string. Whenever a message comes through the set-title channel, this function will find the BrowserWindow instance attached to the message sender and use the win.setTitle API on it.

:::info Make sure you’re loading the index.html and preload.js entry points for the following steps! :::

2. Expose ipcRenderer.send via preload

To send messages to the listener created above, you can use the ipcRenderer.send API. By default, the renderer process has no Node.js or Electron module access. As an app developer, you need to choose which APIs to expose from your preload script using the contextBridge API.

In your preload script, add the following code, which will expose a global window.electronAPI variable to your renderer process.

```javascript title=’preload.js (Preload Script)’ const { contextBridge, ipcRenderer } = require(‘electron’)

contextBridge.exposeInMainWorld(‘electronAPI’, { setTitle: (title) => ipcRenderer.send(‘set-title’, title) })


At this point, you'll be able to use the `window.electronAPI.setTitle()` function in the renderer
process.

:::caution Security warning
We don't directly expose the whole `ipcRenderer.send` API for [security reasons]. Make sure to
limit the renderer's access to Electron APIs as much as possible.
:::

### 3. Build the renderer process UI

In our BrowserWindow's loaded HTML file, add a basic user interface consisting of a text input
and a button:

```html {11-12} title='index.html'
<!DOCTYPE html>
<html>
  <head>
    <meta charset="UTF-8">
    <!-- https://developer.mozilla.org/en-US/docs/Web/HTTP/CSP -->
    <meta http-equiv="Content-Security-Policy" content="default-src 'self'; script-src 'self'">
    <title>Hello World!</title>
  </head>
  <body>
    Title: <input id="title"/>
    <button id="btn" type="button">Set</button>
    <script src="./renderer.js"></script>
  </body>
</html>

To make these elements interactive, we’ll be adding a few lines of code in the imported renderer.js file that leverages the window.electronAPI functionality exposed from the preload script:

```javascript title=’renderer.js (Renderer Process)’ const setButton = document.getElementById(‘btn’) const titleInput = document.getElementById(‘title’) setButton.addEventListener(‘click’, () => { const title = titleInput.value window.electronAPI.setTitle(title) });


At this point, your demo should be fully functional. Try using the input field and see what happens
to your BrowserWindow title!

## Pattern 2: Renderer to main (two-way)

A common application for two-way IPC is calling a main process module from your renderer process
code and waiting for a result. This can be done by using [`ipcRenderer.invoke`] paired with
[`ipcMain.handle`].

In the following example, we'll be opening a native file dialog from the renderer process and
returning the selected file's path.

For this demo, you'll need to add code to your main process, your renderer process, and a preload
script. The full code is below, but we'll be explaining each file individually in the following
sections.

```fiddle docs/fiddles/ipc/pattern-2

1. Listen for events with ipcMain.handle

In the main process, we’ll be creating a handleFileOpen() function that calls dialog.showOpenDialog and returns the value of the file path selected by the user. This function is used as a callback whenever an ipcRender.invoke message is sent through the dialog:openFile channel from the renderer process. The return value is then returned as a Promise to the original invoke call.

:::caution A word on error handling Errors thrown through handle in the main process are not transparent as they are serialized and only the message property from the original error is provided to the renderer process. Please refer to #24427 for details. :::

```javascript {6-13,25} title=’main.js (Main Process)’ const { BrowserWindow, dialog, ipcMain } = require(‘electron’) const path = require(‘path’)

//…

async function handleFileOpen() { const { canceled, filePaths } = await dialog.showOpenDialog() if (canceled) { return } else { return filePaths[0] } }

function createWindow () { const mainWindow = new BrowserWindow({ webPreferences: { preload: path.join(__dirname, ‘preload.js’) } }) mainWindow.loadFile(‘index.html’) }

app.whenReady(() => { ipcMain.handle(‘dialog:openFile’, handleFileOpen) createWindow() }) //…


:::tip on channel names
The `dialog:` prefix on the IPC channel name has no effect on the code. It only serves
as a namespace that helps with code readability.
:::

:::info
Make sure you're loading the `index.html` and `preload.js` entry points for the following steps!
:::

### 2. Expose `ipcRenderer.invoke` via preload

In the preload script, we expose a one-line `openFile` function that calls and returns the value of
`ipcRenderer.invoke('dialog:openFile')`. We'll be using this API in the next step to call the
native dialog from our renderer's user interface.

```javascript title='preload.js (Preload Script)'
const { contextBridge, ipcRenderer } = require('electron')

contextBridge.exposeInMainWorld('electronAPI', {
  openFile: () => ipcRenderer.invoke('dialog:openFile')
})

:::caution Security warning We don’t directly expose the whole ipcRenderer.invoke API for security reasons. Make sure to limit the renderer’s access to Electron APIs as much as possible. :::

3. Build the renderer process UI

Finally, let’s build the HTML file that we load into our BrowserWindow.

```html {10-11} title=’index.html’ <!DOCTYPE html>

Dialog File path:

The UI consists of a single `#btn` button element that will be used to trigger our preload API, and
a `#filePath` element that will be used to display the path of the selected file. Making these
pieces work will take a few lines of code in the renderer process script:

```javascript title='renderer.js (Renderer Process)'
const btn = document.getElementById('btn')
const filePathElement = document.getElementById('filePath')

btn.addEventListener('click', async () => {
  const filePath = await window.electronAPI.openFile()
  filePathElement.innerText = filePath
})

In the above snippet, we listen for clicks on the #btn button, and call our window.electronAPI.openFile() API to activate the native Open File dialog. We then display the selected file path in the #filePath element.

Note: legacy approaches

The ipcRenderer.invoke API was added in Electron 7 as a developer-friendly way to tackle two-way IPC from the renderer process. However, there exist a couple alternative approaches to this IPC pattern.

:::warning Avoid legacy approaches if possible We recommend using ipcRenderer.invoke whenever possible. The following two-way renderer-to-main patterns are documented for historical purposes. :::

:::info For the following examples, we’re calling ipcRenderer directly from the preload script to keep the code samples small. :::

Using ipcRenderer.send

The ipcRenderer.send API that we used for single-way communication can also be leveraged to perform two-way communication. This was the recommended way for asynchronous two-way communication via IPC prior to Electron 7.

```javascript title=’preload.js (Preload Script)’ // You can also put expose this code to the renderer // process with the contextBridge API const { ipcRenderer } = require(‘electron’)

ipcRenderer.on(‘asynchronous-reply’, (_event, arg) => { console.log(arg) // prints “pong” in the DevTools console }) ipcRenderer.send(‘asynchronous-message’, ‘ping’)


```javascript title='main.js (Main Process)'
ipcMain.on('asynchronous-message', (event, arg) => {
  console.log(arg) // prints "ping" in the Node console
  // works like `send`, but returning a message back
  // to the renderer that sent the original message
  event.reply('asynchronous-reply', 'pong')
})

There are a couple downsides to this approach:

Using ipcRenderer.sendSync

The ipcRenderer.sendSync API sends a message to the main process and waits synchronously for a response.

```javascript title=’main.js (Main Process)’ const { ipcMain } = require(‘electron’) ipcMain.on(‘synchronous-message’, (event, arg) => { console.log(arg) // prints “ping” in the Node console event.returnValue = ‘pong’ })


```javascript title='preload.js (Preload Script)'
// You can also put expose this code to the renderer
// process with the `contextBridge` API
const { ipcRenderer } = require('electron')

const result = ipcRenderer.sendSync('synchronous-message', 'ping')
console.log(result) // prints "pong" in the DevTools console

The structure of this code is very similar to the invoke model, but we recommend avoiding this API for performance reasons. Its synchronous nature means that it’ll block the renderer process until a reply is received.

Pattern 3: Main to renderer

When sending a message from the main process to a renderer process, you need to specify which renderer is receiving the message. Messages need to be sent to a renderer process via its WebContents instance. This WebContents instance contains a send method that can be used in the same way as ipcRenderer.send.

To demonstrate this pattern, we’ll be building a number counter controlled by the native operating system menu.

For this demo, you’ll need to add code to your main process, your renderer process, and a preload script. The full code is below, but we’ll be explaining each file individually in the following sections.

```fiddle docs/fiddles/ipc/pattern-3


### 1. Send messages with the `webContents` module

For this demo, we'll need to first build a custom menu in the main process using Electron's `Menu`
module that uses the `webContents.send` API to send an IPC message from the main process to the
target renderer.

```javascript {11-26} title='main.js (Main Process)'
const {app, BrowserWindow, Menu, ipcMain} = require('electron')
const path = require('path')

function createWindow () {
  const mainWindow = new BrowserWindow({
    webPreferences: {
      preload: path.join(__dirname, 'preload.js')
    }
  })

  const menu = Menu.buildFromTemplate([
    {
      label: app.name,
      submenu: [
        {
          click: () => mainWindow.webContents.send('update-counter', 1),
          label: 'Increment',
        },
        {
          click: () => mainWindow.webContents.send('update-counter', -1),
          label: 'Decrement',
        }
      ]
    }
  ])
  Menu.setApplicationMenu(menu)

  mainWindow.loadFile('index.html')
}
//...

For the purposes of the tutorial, it’s important to note that the click handler sends a message (either 1 or -1) to the renderer process through the update-counter channel.

click: () => mainWindow.webContents.send('update-counter', -1)

:::info Make sure you’re loading the index.html and preload.js entry points for the following steps! :::

2. Expose ipcRenderer.on via preload

Like in the previous renderer-to-main example, we use the contextBridge and ipcRenderer modules in the preload script to expose IPC functionality to the renderer process:

```javascript title=’preload.js (Preload Script)’ const { contextBridge, ipcRenderer } = require(‘electron’)

contextBridge.exposeInMainWorld(‘electronAPI’, { onUpdateCounter: (callback) => ipcRenderer.on(‘update-counter’, callback) })


After loading the preload script, your renderer process should have access to the
`window.electronAPI.onUpdateCounter()` listener function.

:::caution Security warning
We don't directly expose the whole `ipcRenderer.on` API for [security reasons]. Make sure to
limit the renderer's access to Electron APIs as much as possible.
:::

:::info
In the case of this minimal example, you can call `ipcRenderer.on` directly in the preload script
rather than exposing it over the context bridge.

```javascript title='preload.js (Preload Script)'
const { ipcRenderer } = require('electron')

window.addEventListener('DOMContentLoaded', () => {
    const counter = document.getElementById('counter')
    ipcRenderer.on('update-counter', (_event, value) => {
        const oldValue = Number(counter.innerText)
        const newValue = oldValue + value
        counter.innerText = newValue
    })
})

However, this approach has limited flexibility compared to exposing your preload APIs over the context bridge, since your listener can’t directly interact with your renderer code. :::

3. Build the renderer process UI

To tie it all together, we’ll create an interface in the loaded HTML file that contains a #counter element that we’ll use to display the values:

```html {10} title=’index.html’ <!DOCTYPE html>

Menu Counter Current value: 0

Finally, to make the values update in the HTML document, we'll add a few lines of DOM manipulation
so that the value of the `#counter` element is updated whenever we fire an `update-counter` event.

```javascript title='renderer.js (Renderer Process)'
const counter = document.getElementById('counter')

window.electronAPI.onUpdateCounter((_event, value) => {
    const oldValue = Number(counter.innerText)
    const newValue = oldValue + value
    counter.innerText = newValue
})

In the above code, we’re passing in a callback to the window.electronAPI.onUpdateCounter function exposed from our preload script. The second value parameter corresponds to the 1 or -1 we were passing in from the webContents.send call from the native menu.

Optional: returning a reply

There’s no equivalent for ipcRenderer.invoke for main-to-renderer IPC. Instead, you can send a reply back to the main process from within the ipcRenderer.on callback.

We can demonstrate this with slight modifications to the code from the previous example. In the renderer process, use the event parameter to send a reply back to the main process through the counter-value channel.

```javascript title=’renderer.js (Renderer Process)’ const counter = document.getElementById(‘counter’)

window.electronAPI.onUpdateCounter((event, value) => { const oldValue = Number(counter.innerText) const newValue = oldValue + value counter.innerText = newValue event.sender.send(‘counter-value’, newValue) })


In the main process, listen for `counter-value` events and handle them appropriately.

```javascript title='main.js (Main Process)'
//...
ipcMain.on('counter-value', (_event, value) => {
  console.log(value) // will print value to Node console
})
//...

Pattern 4: Renderer to renderer

There’s no direct way to send messages between renderer processes in Electron using the ipcMain and ipcRenderer modules. To achieve this, you have two options:

Object serialization

Electron’s IPC implementation uses the HTML standard Structured Clone Algorithm to serialize objects passed between processes, meaning that only certain types of objects can be passed through IPC channels.

In particular, DOM objects (e.g. Element, Location and DOMMatrix), Node.js objects backed by C++ classes (e.g. process.env, some members of Stream), and Electron objects backed by C++ classes (e.g. WebContents, BrowserWindow and WebFrame) are not serializable with Structured Clone.